Development and Initial Field Evaluation of an Internet of Things-Based Household Environmental Monitoring System in Tuberculosis-Affected Homes in Muaro Jambi Regency

Main Article Content

Zunidra
Jessy Novita Sari
Erwin Hari Astuti
Heru Subaris Kasjono
Nunuk Sri Purwanti

Abstract

Household microclimate conditions and the limitations of periodic monitoring may hinder environmental control in the homes of people with tuberculosis (TB). This study developed and evaluated an Internet of Things (IoT)-based monitoring system for real-time measurement of household temperature, humidity, and illuminance. A development study with a one-group pretest-posttest field evaluation was conducted in 44 homes of people with TB in the service area of Penyengat Olak Primary Health Center, Muaro Jambi Regency. A seven-day passive observation phase was followed by 21 days of active feedback. Sensor accuracy was tested against reference instruments. Changes in the proportion of time within operational thresholds and behavioral scores were analyzed using paired t-tests, while the association between notification response and environmental index change was examined using Pearson correlation. At baseline, 33 homes (75.0%) failed to meet the humidity criterion, 30 (68.2%) failed the temperature criterion, and 34 (77.3%) failed the illuminance criterion. The mean proportion of time meeting the composite thresholds increased from 36.2% to 54.4% (difference 18.2 percentage points; 95% CI 14.1–22.3; p<0.001; d=1.34). The behavioral score increased from 62.1 to 78.4 (difference 16.3; 95% CI 12.7–19.9; p<0.001), and improvement in the environmental index correlated with notification response (r=0.48; p=0.001). The system usability score was 82.3. The IoT system provided accurate and acceptable household environmental monitoring and may support improvements in conditions and household-management behaviors relevant to TB transmission prevention.

Article Details

How to Cite
Zunidra, Z., Sari, J. N. ., Astuti, E. H. ., Kasjono, H. S. ., & Purwanti, N. S. . (2026). Development and Initial Field Evaluation of an Internet of Things-Based Household Environmental Monitoring System in Tuberculosis-Affected Homes in Muaro Jambi Regency. Journal of Community Health Provision, 6(3), 1043-1054. https://doi.org/10.55885/jchp.v6i3.1196
Section
Articles

References

Al-Fuqaha, A., Guizani, M., Mohammadi, M., Aledhari, M., & Ayyash, M. (2015). Internet of Things: A survey on enabling technologies, protocols, and applications. IEEE Communications Surveys & Tutorials, 17(4), 2347–2376. https://doi.org/10.1109/COMST.2015.2444095

Arsad, F. S., Hod, R., Ahmad, N., Baharom, M., Ja’afar, M. H., et al. (2023). Assessment of indoor thermal comfort temperature and related behavioural adaptations: A systematic review. Environmental Science and Pollution Research, 30, 73137–73149. https://doi.org/10.1007/s11356-023-27089-9

ASHRAE. (2022). ASHRAE position document on infectious aerosols. American Society of Heating, Refrigerating and Air-Conditioning Engineers.

Banholzer, N., Schmutz, R., Middelkoop, K., Hella, J., Egger, M., Wood, R., et al. (2024). Airborne transmission risks of tuberculosis and COVID-19 in schools in South Africa, Switzerland, and Tanzania: Modeling of environmental data. PLOS Global Public Health, 4(1), e0002800. https://doi.org/10.1371/journal.pgph.0002800

Beckwith, P. G., Karat, A. S., Govender, I., Deol, A. K., McCreesh, N., Kielmann, K., Baisley, K., Grant, A. D., & Yates, T. A. (2022). Direct estimates of absolute ventilation and estimated Mycobacterium tuberculosis transmission risk in clinics in South Africa. PLOS Global Public Health, 2(11), e0000603. https://doi.org/10.1371/journal.pgph.0000603

Bentley, R., Mason, K., Jacobs, D., Blakely, T., Howden-Chapman, P., Li, A., ... & Reeves, A. (2025). Housing as a social determinant of health: a contemporary framework. The Lancet Public Health, 10(10), e855-e864.

Calì, D., Andersen, R. K., Müller, D., & Olesen, B. W. (2016). Analysis of occupants' behavior related to the use of windows in German households. Building and Environment, 103, 54-69. https://doi.org/10.1016/j.buildenv.2016.03.024

Cohen, J. (1988). Statistical power analysis for the behavioral sciences (2nd ed.). Lawrence Erlbaum Associates.

Coleman, M., Martinez, L., Theron, G., Wood, R., & Marais, B. (2022). Mycobacterium tuberculosis transmission in high-incidence settings—New paradigms and insights. Pathogens, 11(11), 1228. https://doi.org/10.3390/pathogens11111228

Cronbach, L. J. (1951). Coefficient alpha and the internal structure of tests. Psychometrika, 16, 297–334. https://doi.org/10.1007/BF02310555

Deol, A. K., Shaikh, N., Middelkoop, K., Mohlamonyane, M., White, R. G., & McCreesh, N. (2022). Importance of ventilation and occupancy to Mycobacterium tuberculosis transmission rates in congregate settings. BMC Public Health, 22, Article 1772. https://doi.org/10.1186/s12889-022-14133-5

Des Jarlais, D. C., Lyles, C., Crepaz, N., & TREND Group. (2004). Improving the reporting quality of nonrandomized evaluations of behavioral and public health interventions: The TREND statement. American Journal of Public Health, 94(3), 361–366. https://doi.org/10.2105/AJPH.94.3.361

Du, C., Yu, W., Ma, Y., Cai, Q., Li, B., Li, N., ... & Yao, R. (2021). A holistic investigation into the seasonal and temporal variations of window opening behavior in residential buildings in Chongqing, China. Energy and Buildings, 231, 110522.

Escombe, A. R., Oeser, C. C., Gilman, R. H., Navincopa, M., Ticona, E., Pan, W., Martínez, C., Chacaltana, J., Rodríguez, R., Moore, D. A. J., Friedland, J. S., & Evans, C. A. (2007). Natural ventilation for the prevention of airborne contagion. PLOS Medicine, 4(2), e68. https://doi.org/10.1371/journal.pmed.0040068

Fennelly, K. P. (2020). Particle sizes of infectious aerosols: Implications for infection control. The Lancet Respiratory Medicine, 8(9), 914–924. https://doi.org/10.1016/S2213-2600(20)30323-4

Gabel, C., Sigsgaard, T., Petersen, S., Elholm, G., et al. (2024). The prevalence and association of measured and perceived indoor air quality, housing characteristics, and residents’ behavior and health. Frontiers in Environmental Health, 3, Article 1358546. https://doi.org/10.3389/fenvh.2024.1358546

Giri, A., García-Sánchez, C., & Bluyssen, P. M. (2024). Quantifying airborne transmission in ventilated settings: A review. Building and Environment, 266, Article 112049. https://doi.org/10.1016/j.buildenv.2024.112049

Higgins, C., Kumar, P., & Morawska, L. (2024). Indoor air quality monitoring and source apportionment using low-cost sensors. Environmental research communications, 6(1), 012001.

Hobeika, N., García-Sánchez, C., & Bluyssen, P. M. (2023). Assessing indoor air quality and ventilation to limit aerosol dispersion—Literature review. Buildings, 13(3), Article 742. https://doi.org/10.3390/buildings13030742

Hou, J., Sun, Y., Dai, X., Liu, J., Shen, X., Tan, H., Yin, H., Huang, K., Gao, Y., Lai, D., Hong, W., Zhai, X., Norbäck, D., & Chen, Q. (2021). Associations of indoor carbon dioxide concentrations, air temperature, and humidity with perceived air quality and sick building syndrome symptoms in Chinese homes. Indoor Air, 31(4), 1018–1028. https://doi.org/10.1111/ina.12810

Islam, S. M. R., Kwak, D., Kabir, M. H., Hossain, M., & Kwak, K. S. (2015). The Internet of Things for health care: A comprehensive survey. IEEE Access, 3, 678–708. https://doi.org/10.1109/ACCESS.2015.2437951

Izadyar, N., & Miller, W. (2022). Ventilation strategies and design impacts on indoor airborne transmission: A review. Building and Environment, 218, Article 109158. https://doi.org/10.1016/j.buildenv.2022.109158

Jebeile, H., Kelly, A. S., O'Malley, G., & Baur, L. A. (2022). Obesity in children and adolescents: epidemiology, causes, assessment, and management. The lancet Diabetes & endocrinology, 10(5), 351-365.

Koo, T. K., & Li, M. Y. (2016). A guideline of selecting and reporting intraclass correlation coefficients for reliability research. Journal of Chiropractic Medicine, 15(2), 155–163. https://doi.org/10.1016/j.jcm.2016.02.012

Kumar, P., Morawska, L., Martani, C., Biskos, G., Neophytou, M., Di Sabatino, S., Bell, M., Norford, L., & Britter, R. (2015). The rise of low-cost sensing for managing air pollution in cities. Environment International, 75, 199–205. https://doi.org/10.1016/j.envint.2014.11.019

Liu, G., Chen, H., Yuan, Y., & Song, C. (2024). Indoor thermal environment and human health: A systematic review. Renewable and Sustainable Energy Reviews, 191, Article 114164. https://doi.org/10.1016/j.rser.2023.114164

Lönnroth, K., Jaramillo, E., Williams, B. G., Dye, C., & Raviglione, M. (2009). Drivers of tuberculosis epidemics: The role of risk factors and social determinants. Social Science & Medicine, 68(12), 2240–2246. https://doi.org/10.1016/j.socscimed.2009.03.041

Marques, G., & Pitarma, R. (2020). Development of an indoor air quality monitoring platform. Journal of Sensors, 2020, Article 8749764. https://doi.org/10.1155/2020/8749764

Marques, G., Saini, J., Dutta, M., Singh, P. K., & Hong, W. C. (2020). Indoor air quality monitoring systems for enhanced living environments: A review toward sustainable smart cities. Sustainability, 12(10), 4024. https://doi.org/10.3390/su12104024

Marr, L. C., Tang, J. W., Van Mullekom, J., & Lakdawala, S. S. (2019). Mechanistic insights into the effect of humidity on airborne influenza virus survival, transmission and incidence. Journal of the Royal Society Interface, 16(150), Article 20180298. https://doi.org/10.1098/rsif.2018.0298

McIntosh, A. I., Jenkins, H. E., White, L. F., Barnard, M., Thomson, D. R., Dolby, T., ... & Jacobson, K. R. (2018). Using routinely collected laboratory data to identify high rifampicin-resistant tuberculosis burden communities in the Western Cape Province, South Africa: A retrospective spatiotemporal analysis. PLoS Medicine, 15(8), e1002638. https://doi.org/10.1371/journal.pmed.1002638

Michie, S., van Stralen, M. M., & West, R. (2011). The behaviour change wheel: A new method for characterising and designing behaviour change interventions. Implementation Science, 6, Article 42. https://doi.org/10.1186/1748-5908-6-42

Moore, J., Goffin, P., Meyer, M., Lundrigan, P., Patwari, N., Sward, K., & Wiese, J. (2018). Managing in-home environments through sensing, annotating, and visualizing air quality data. Proceedings of the ACM on interactive, mobile, wearable and ubiquitous technologies, 2(3), 1-28. https://doi.org/10.1145/3264938

Nahum-Shani, I., Smith, S. N., Spring, B. J., Collins, L. M., Witkiewitz, K., Tewari, A., & Murphy, S. A. (2018). Just-in-time adaptive interventions in mobile health: Key components and design principles for ongoing health behavior support. Annals of Behavioral Medicine, 52(6), 446–462. https://doi.org/10.1007/s12160-016-9830-8

Nardell, E. A. (2016). Indoor environmental control of tuberculosis and other airborne infections. Indoor Air, 26(1), 79–87. https://doi.org/10.1111/ina.12232

Othman, H., Azari, R., & Guimarães, T. (2024). Low-cost IoT-based indoor air quality monitoring. Technology|Architecture + Design, 8(2), 250–270.

Park, J., & Choi, C. S. (2019). Modeling occupant behavior of the manual control of windows in residential buildings. Indoor Air, 29(2), 242-251. https://doi.org/10.1111/ina.12522

Parkins, M. D., Lee, B. E., Acosta, N., Bautista, M., Hubert, C. R., Hrudey, S. E., ... & Pang, X. L. (2024). Wastewater-based surveillance as a tool for public health action: SARS-CoV-2 and beyond. Clinical microbiology reviews, 37(1), e00103-22. https://doi.org/10.1128/cmr.00103-22

Patterson, B., Morrow, C., Singh, V., Moosa, A., Gqada, M., Woodward, J., Mizrahi, V., Bryden, W., Call, C., Patel, S., Warner, D. F., & Wood, R. (2017). Detection of Mycobacterium tuberculosis bacilli in bio-aerosols from untreated TB patients. Gates Open Research, 1, Article 11. https://doi.org/10.12688/gatesopenres.12758.2

Saini, J., Dutta, M., & Marques, G. (2020). Indoor air quality monitoring systems based on Internet of Things: A systematic review. International Journal of Environmental Research and Public Health, 17(14), Article 4942. https://doi.org/10.3390/ijerph17144942

Shapiro, S. S., & Wilk, M. B. (1965). An analysis of variance test for normality. Biometrika, 52(3–4), 591–611. https://doi.org/10.1093/biomet/52.3-4.591

Sharpe, R. A., Taylor, T., Fleming, L. E., Morrissey, K., Morris, G., & Wigglesworth, R. (2018). Making the case for “whole system” approaches: Integrating public health and housing. International journal of environmental research and public health, 15(11), 2345. https://doi.org/10.3390/ijerph15112345

Shrestha, S., Gandhi, N. R., Hill, A. N., et al. (2023). Quantifying Mycobacterium tuberculosis transmission dynamics across global settings: A systematic analysis. American Journal of Epidemiology, 192(1), 133–145. https://doi.org/10.1093/aje/kwac181

Vesga, J. F., Hallett, T. B., Reid, M. J., Sachdeva, K. S., Rao, R., Khaparde, S., ... & Arinaminpathy, N. (2019). Assessing tuberculosis control priorities in high-burden settings: a modelling approach. The Lancet Global Health, 7(5), e585-e595.

von Elm, E., Altman, D. G., Egger, M., Pocock, S. J., Gøtzsche, P. C., & Vandenbroucke, J. P. (2007). The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: Guidelines for reporting observational studies. PLOS Medicine, 4(10), e296. https://doi.org/10.1371/journal.pmed.0040296

Wolkoff, P., Azuma, K., & Carrer, P. (2021). Health, work performance, and risk of infection in office-like environments: The role of indoor temperature, air humidity, and ventilation. International Journal of Hygiene and Environmental Health, 233, Article 113709. https://doi.org/10.1016/j.ijheh.2021.113709

Zhang, Z., Lv, X., Wei, Z., Guan, J., Zhang, Y., Chen, S., & He, H. (2022). Effects of cooking and window opening behaviors on indoor ultrafine particle concentrations in urban residences: A field study in Yangtze River Delta region of China. Building and Environment, 207, 108488.